Tips, Tricks, & Troubleshooting: Tapmaster
Having minor difficulties with the Installation of your Tapmaster? Here are a couple of tips and tricks to fix and problems you may be having:
If the faucet drips:
First determine which valve is at fault, one of the valve blocks or the pilot/actuator valve by shutting off, in turn, with the faucet handle(s) the cold and hot water. If the dripping stops the corresponding valve block requires service, go to the valve block service procedure. If the faucet did not stop dripping, pinch off the yellow tube between the pilot/actuator valve and first valve block with a pair of needle nose pliers (pinch closed only, DO NOT CRUSH). If the dripping stops replace the pilot/actuator valve.
The water is very slow to shutoff or will not shutoff:
Turn off the hot and cold water supplies. Disconnect a green tube from one of the valve block barbs by prying back the sleeve and splitting the tube with a sharp knife (DO NOT overstress the barb it may break). Open the cold water supply shutoff partially while holding a small container under the appropriate green tube or barb fitting to catch the water. A strong steady stream should result. Using the same procedure test the flow from the hot valve block. If there is little or no flow go to the valve block service procedure. If the flow is good from the green tube connections, on both valve blocks, reconnect the green tube and disconnect the blue tube coming from the pilot/actuator valve at the valve block. Again using the same procedure, test the water flow coming from the blue tube. If there is little or no flow replace the pilot/actuator valve.
Need to purchase more Tapmasters? Click here!
The water is very slow to turn on or will not turn on:
First verify pedal top is making solid contact with the pilot/actuator valve by removing the pedal top and operating the valve by hand. Next verify there is good flow in the blue tube from the pilot/actuator valve using the same procedure as in the above situation. If there is good flow reconnect the blue tube and disconnect the yellow tube coming from the pilot/actuator valve. With the water supplies turned on press the pilot/actuator valve while observing the water flow coming from the yellow tube. If there is a short burst of water go to the valve block service procedure. If there is none or just a few drops of water, replace the pilot/actuator valve.
Noise from valve blocks while the water is running:
Turn off the cold and hot water alternately at the faucet to determine which valve block is the source of the noise. The corresponding valve block may have excessive debris trapped under its filter-screen and requires service. See the valve block service procedure.
Tapmaster turns off by itself and/or turns on when the toilet is flushed:
This behavior can be caused by a drop in pressure in the cold water line or a blockage in the green tube attached on the 6 barb waterline block. To fix this, remove the green tube from the 6 barb manifold on the waterline block, on the side going towards the actuator valve (cabinet door valve, kickplate valve, euro switch, etc.). Then, activate the Tapmaster and look to see if the water flows through the barb. If it does not flow, use a thin needle or pin and insert it into the barb to clear the blockage. Test again to ensure the water is flowing and reattach the green tube to the barb.
Want to learn more about the 1775 Tapmaster
Valve Block Service Procedure:
Turn off the water supply(s) and disassemble the valve block by removing the four hex screws, take care not to lose the spring (see the illustrated breakdown). Remove the diaphragm and the filter-screen, clean all the ports in the body and manifold with vinegar or a commercial water deposit cleaner while paying particular attention to the small passages. Inspect the filter-screen and diaphragm and clean or replace as required (note: the filter-screen is a dual purpose part which functions both as a coarse screen for the main water flow and is a porous plastic with 25 micron filtration to protect the control circuits). Reassemble the valve block as per the illustrated breakdown and pay particular attention to the alignment of the body diaphragm and manifold. Take care not to crush the duck bill check valves on the diaphragm. Tighten the screws in an alternating crossing pattern. (hint: if the valve block is mounted use a little Vaseline or silicone grease to hold the spring in place).
Still having troubles?
We also offer bulk pricing for contractors and businesses! Check here!
Visit out FAQ page for Tapmaster – https://conservastore.com/product/shop-by-room/kitchen/tapmaster-euro-hands-free-faucet-controller-model-1775/
As always, www.customwordpresssites.com/conservastoreGreen Solutions for Your Life!
Contact Us: 407.898.2284
Email Us: info@conservastore.com/conservastore